2.224 bytes

Service Hints & Tips

Document ID: GSMH-3ABE7W

PC Server 500 - False video diagnostic errror message

Applicable to: World-Wide

Symptom
While running Advanced Diagnostics on the Server 500 (8641) SVGA (video) Adapter/A, the following intermittent error message is seen:
Error Code = 02610450
Error in the display
1. Replace the display.
2. Rerun the video Diagnostic tests.

Problem Isolation Aids
The video subsystem consists of the SVGA Adapter, FRU P/N71G0650, and any of the following displays: 851X, 632X or 952X.
The Advanced Diagnostics is version 2.32.
Replacement of the monitor or the video adapter does not correct the problem.

Fix
This is a diagnostic software error. No parts should be replaced. The problem has been corrected in Advanced Diagnostics version 2.33, or later.

SAS Keywords:
PSY2, SERVER, 500, PSY2DISP, PSY2ERR, PSY2DIAG, RAID, 02610950

Search Keywords

Hint Category

Diagnostics, Retain

Date Created

09-10-95

Last Updated

13-11-98

Revision Date

05-11-99

Brand

IBM PC Server

Product Family

PC Server 500

Machine Type

8641

Model

TypeModel

Retain Tip (if applicable)

H131011

Reverse Doclinks