2.224 bytes |
Service Hints & Tips |
Document ID: GSMH-3ABE7W |
PC Server 500 - False video diagnostic errror message
Applicable to: World-Wide
Symptom
While running Advanced Diagnostics on the Server 500 (8641) SVGA (video) Adapter/A, the following intermittent error message is seen:
Error Code = 02610450
Error in the display
1. Replace the display.
2. Rerun the video Diagnostic tests.
Problem Isolation Aids
The video subsystem consists of the SVGA Adapter, FRU P/N71G0650, and any of the following displays: 851X, 632X or 952X.
The Advanced Diagnostics is version 2.32.
Replacement of the monitor or the video adapter does not correct the problem.
Fix
This is a diagnostic software error. No parts should be replaced. The problem has been corrected in Advanced Diagnostics version 2.33, or later.
SAS Keywords:
PSY2, SERVER, 500, PSY2DISP, PSY2ERR, PSY2DIAG, RAID, 02610950
Search Keywords |
| |
Hint Category |
Diagnostics, Retain | |
Date Created |
09-10-95 | |
Last Updated |
13-11-98 | |
Revision Date |
05-11-99 | |
Brand |
IBM PC Server | |
Product Family |
PC Server 500 | |
Machine Type |
8641 | |
Model |
| |
TypeModel |
| |
Retain Tip (if applicable) |
H131011 | |
Reverse Doclinks |