1.803 bytes

Service Hints & Tips

Document ID: RMIE-385BXJ

This document is provided to IBM and our Business Partners to help sell and/or service IBM products. It is not to be distributed beyond that audience or used for any other purpose.

TP 760E/ED/EL/ELD - Error with Windows 95

Applicable to: World-Wide

Subject :
760 Suspend/Resume Error Message

The following problem was found/fixed in manufacturing; however we may get some calls with this error.

System : 760 "E" systems with W95

Symptom :
When attempting to resume from Suspend mode, get the following error message: "Invalid VxD Dynamic Link call from IBMPCDIF(03)+00000IBD to device "097C", service 1. Your Windows Configuration is Invalid. Run the Windows Setup Program again to correct this problem..."
CAUSE: Incompatability between preload image (RFBWEUS) and bios prior to 15/5/96.

Fix :
Have customer flash bios to 15/5/96 or later. DO NOT EASYSERVE.