2.947 bytes

Service Hints & Tips

Document ID: DJON-3LXVWD

TP 770 - Other Symptoms

Applicable to: World-Wide

Symptom / Error

FRU / Action in Sequence

Errors occur only when the port replicator is used.

See Port Replicator Checkout


Note: If you cannot find a symptom or error in this list and the problem persists, see Undetermined Problems.

Intermittent Symptoms
Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement should be considered only when a recurring problem exists.

When analyzing the intermittent problem, do the following:
1. Run the advanced diagnostic test for the system board in loop mode at least 10 times.
2. If no error is detected, do not replace any FRUs.
3. If any error is detected, replace the FRU shown by the FRU code. Rerun the test to verify that no more errors exist.

Search Keywords

Hint Category

Hardware Maintenance Information

Date Created

16-09-97

Last Updated

19-01-99

Revision Date

19-01-2000

Brand

IBM ThinkPad

Product Family

ThinkPad 770, ThinkPad 770E/ED, ThinkPad 770X

Machine Type

9548, 9549, 9544

Model

All

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes