4.900 bytes

Service Hints & Tips

Document ID: DSHY-3PVTLY

TP Selectadock III - SymptomToFRU Index - Numeric Error Codes

Applicable to: World-Wide

Symptom or Error

FRUs of the SelectaDock Sequence of Actions

10X, 11x
101: Interrupt failure.
102: Timer failure.
103: Timer interrupt failure.
104: Protected mode failure.
105: Last 8042 command not accepted.
107: NMI test failure.
108: Timer bus test failure.
109: Low meg-chip select test.

1. Adapter in slot (if used).
2. Riser card.
3. Main card.

195

1. Do the following steps:

(The computer was docked to the SelectaDock Docking System while in hibernation mode.)

a. Turn off and undock the system.
b. Turn on and shut down the system.
c. Turn off and dock the system.

1XX

See the hardware maintenance manual for the computer. If the problem persists, go to "Undetermined Problems" in topic 7.6.

2XX
201: Memory data error.
202: Memory line error 00-15.
203: Memory line error 16-23.
205: Memory test failure on on-board memory.
221: ROM to RAM remap error.

1. See the hardware maintenance manual for the computer.
2. Main card.

3XX

See "External Keyboard" in topic 7.3.3.

6XX

1. Before changing any devices, run the diagnostic test.
2. FDD external attachment kit.
3. Diskette drive assembly.
4. Riser card.

11XX, 12XX

1. Serial devices.
2. Communication cable.
3. Riser card.

17XX

1. Hard disk drive (2.5-inch ThinkPad hard disk drive).
2. Main card.

24XX

1. Main card.
2. Riser card.

860X

1. Mouse.
2. External keyboard.
3. Riser card.

I9990301, I9990302, I9990305

See the hardware maintenance manual for the computer.

Not shown above

1. See the hardware maintenance manual for the computer.
2. See "Undetermined Problems"



Search Keywords

Hint Category

Hardware Maintenance Information

Date Created

05-12-97

Last Updated

28-08-98

Revision Date

21-08-99

Brand

IBM ThinkPad

Product Family

ThinkPad Docking Stations

Machine Type

3547

Model

003

TypeModel

Retain Tip (if applicable)

N/A

Reverse Doclinks
and Admin Purposes