4.837 bytes

Service Hints & Tips

Document ID: MCGN-459D8J

Netfinity 5500 / 5500 M10 - Use of SSA Adapters

Applicable to: World-Wide

Source: RETAIN tip H165897

Abstract: NETFINITY 5500 & 5500-M10: USE OF SSA ADAPTERS

SYMPTOM:
System may be unreliable during heavy loading, Blue Screen may result.

Power may not be supplied to SSA adapter and hence it will not function.

PROBLEM ISOLATION AIDS:
The system is one of the following Netfinity servers:


The system is configured with one of the following:


P/Ns affected:


FIX:
Ensure that no more than one (1) SSA adapter card is used on the primary bus (PCI Bus/0, slots 5 and 6) of the Netfinity 5500 and Netfinity 5500-M10 Servers.

Ensure that the following SSA adapters are not used on the secondary bus (PCI Bus/1, slots 1,2,3 and 4) of the Netfinity 5500 and Netfinity 5500-M10 Servers:


DETAILS:
If any of the referenced SSA adapters are being used in either the Netfinity 5500 or 5500 M10 servers, no more than one (1) SSA adapter should be installed on the primary bus slots (PCI bus/0, slots 5 and 6). If an SSA adapter is installed on the primary bus, then no other PC adapters of any type should be used on the primary bus.

If more than one (1) SSA adapter is installed on the primary bus, or if another type of PC adapter is used on the primary bus as well as an SSA adapter, then under heavy loading the reliability of the system may be affected and a blue screen may result.

The following SSA adapters cannot be used in the secondary bus slots (PCI bus/1, slots 1,2,3 and 4) of either the Netfinity 5500 or 5500 M10 servers:


If either the IBM SSA RAID Adapter for PC Servers (Option p/n32H3811), or the IBM SSA RAID Cluster Adapter for PC Servers (Option p/n96H9835), are used in the secondary bus slots, and disks are attached to the adapter, then power will not be supplied to the adapters. Hence the adapters will not function.

Note: There are NO restrictions for using the IBM SerialRAID Adapter, Option p/n09L2084, on the secondary bus.

SAS KEYWORDS:
PSY2, ADAPTER, NETFINITY, UNCLASSIFIED, 5500-M10, D/T8661, 5500, D/T8660, 09L2066, 09L2069, 09L2084, 09L2130, 09L5507, 09L5544, 32H3811, 96H9835, CLUSTER, FC4011, FC4012, FC4013, RAID, SSA, SERIALRAID

Search Keywords

PSY2, ADAPTER, NETFINITY, UNCLASSIFIED, 5500-M10, D/T8661, 5500, D/T8660, 09L2066, 09L2069, 09L2084, 09L2130, 09L5507, 09L5544, 32H3811, 96H9835, CLUSTER, FC4011, FC4012, FC4013, RAID, SSA, SERIALRAID

Document Category

RAID, Retain

Date Created

19-02-99

Last Updated

19-02-99

Revision Date

Brand

IBM PC Server

Product Family

Clustering, Netfinity 5500, Netfinity 5500 M10

Machine Type

8660, 8661

Model

TypeModel

Retain Tip (if applicable)

H165897

Reverse Doclinks
and Admin Purposes

Date last altered: A99/02/09