2.394 bytes |
Product Information |
Document ID: MCGN-46ARJJ |
Netfinity EXP10 - Performing a shutdown and turning the power on
Applicable to: World-Wide
Performing a Shutdown
Note: If the Expansion Unit loses power unexpectedly, it might be due to a hardware failure in the power system or mid-plane (see "Symptom-to-FRU Index").
To perform a shutdown:
1. If possible, stop all activity and check the LEDs (front and back). Make note of any fault LEDs that may be lit so you can correct the problem when you turn on
the power again.
2. Turn off both power supply switches; then, unplug both power cords from the Expansion Unit.
Turning the Power On
Use this procedure to power on the Netfinity EXP10 Storage Expansion unit.
Initial start-up:
1. Verify that all communication and power cables are plugged into the back of the Expansion Unit.
a. All hard disk drives are locked securely in place.
b. The Option ID switches on the Expansion Unit are set correctly.
c. The host controller and other SCSI bus devices are ready for the initial power-up.
d. Check the system documentation for all the hardware devices you intend to power-up and determine the proper startup sequence.
2. Turn on the power to each device, based on this power-up sequence.
3. Turn on both power supply switches on the back of the Expansion Unit.
4. Only the green LEDs on the front and back should be on. If one or more of the amber Fault LEDs are on refer to "Symptom-to-FRU Index".
Re-starting:
If you are re-starting after a normal shutdown, wait at least ten seconds before you attempt to turn on both power supply switches.
Search Keywords |
| |
Document Category |
General Information | |
Date Created |
24-03-99 | |
Last Updated |
21-05-99 | |
Revision Date |
24-03-2000 | |
Brand |
IBM PC Server | |
Product Family |
Rack/Storage Enclosures | |
Machine Type |
3520 | |
Model |
ALL | |
TypeModel |
| |
Retain Tip (if applicable) |
| |
Reverse Doclinks |