4.236 bytes

Service Hints & Tips

Document ID: GSMH-3GNCSM

IBM PC300XL (Type 6588) - Specifications

Applicable to: World-Wide

PC300XL (Type 6588) Specifications

Feature

Description

Size

Depth: 475 mm (18.7 inches)
Height: 157 mm (6.2 inches)
Width: 419 mm (16.5 inches)

Weight

Weight: 14.1 kg (31.0 pounds) 19

Environment

Air temperature:
- System on: 10o to 35oC (50o to 95oF)
- System off: 10o to 43oC (50o to 110oF)

Humidity:
- System on: 8% to 80%
- System off: 8% to 80%
Maximum altitude: 2134 m (7000 ft)

Heat Output

Approximate heat output in BTUs per hour:
- Minimum: 120 BTU (35 Watts)
- Maximum: 700 BTU (204 Watts) 20
- Deep sleep: 15 BTU (4 Watts)

Electrical Input

Sine-wave input (50 to 60 Hz) required.
Low Range Input Voltage:
- Minimum: 90 volts ac
- Maximum: 137 volts ac
High Range Input Voltage:
- Minimum: 180 volts ac
- Maximum: 265 volts ac
Input kVA (approximately):
- Minimum: 0.08 kVA
- Maximum: 0.52 kVA

Airflow

Approximately 0.56 cubic meters/minute
(20 CFM)

Acoustical
Noise Emmision
Values

Average sound pressure levels:
At operator position:
- 43 dB operating
- 38 dB idle
At bystander position (1 meter):
- 37 dB operating
- 33 dB idle
Declared (upper limit) sound power levels:
- 5.3 dB operating
- 4.9 dB idle


19 Maximum configuration weight depends on options installed.
Figures above are a system fully populated with options.
20 Maximum power and heat specifications are based on the 200-watt
maximum capacity of the system power supply.

Search Keywords

Hint Category

Hardware Maintenance Information

Date Created

01-05-97

Last Updated

28-04-98

Revision Date

21-04-99

Brand

IBM PC

Product Family

PC 300XL

Machine Type

6588

Model

various

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes