IBM ThinkPad Dock I FRUs Sequence of Actions

10X, 11X
101: Interrupt failure.
102: Timer failure.
103: Timer interrupt failure.
104.: Protected mode failure.
105: Last 8042 command not accepted.
107: NMI test failure.
108: Timer bus test failure.
109: Low meg-chip select test.

1. Adapter in slot (if used)
2. Riser card
3. Main card

195
(The computer was docked to the IBM ThinkPad Dock I while in hibernation mode.)

1. Do the following steps.
a. Power-off and undock the system.
b. Power-on and shut down the system.
c. Power-off and dock the system.

1XX

See the Hardware Maintenance Manual of the computer. If the problem remains, go to Undetermined Problems

2XX
201: Memory data error.
202: Memory line error 00-15.
203: Memory line error 16-23.
205: Memory test failure on on-board memory.
221: ROM to RAM remap error.

1. See the Hardware Maintenance Manual of the computer.
2. Main card

3XX

See External Keyboard

6XX

1. Before changing any devices, run the diagnostic test. (See the How to Run the Diagnostics)
2. FDD external attachment kit
3. Diskette drive assembly
4. Riser card

11XX, 12XX

1. Serial devices
2. Communication cable
3. Riser card

17XX

1. Hard disk drive (2.5-inch ThinkPad hard disk drive)
2. Main card

24XX

1. Main card
2. Riser card

860X

1. Mouse
2. External keyboard
3. Riser card

I9990301, I9990302 I9990305

See the Hardware Maintenance Manual of the computer.

Not shown above

1. See the Hardware Maintenance Manual of the computer.
2. See Undetermined Problems



Search Keywords

Hint Category

Hardware Maintenance Information

Date Created

02-08-96

Last Updated

27-08-98

Revision Date

21-08-99

Brand

IBM ThinkPad

Product Family

ThinkPad Docking Stations

Machine Type

3547

Model

001

TypeModel

Retain Tip (if applicable)

Reverse Doclinks