1.965 bytes |
Service Hints & Tips |
Document ID: MCGN-42AN4W |
IBM PC 8590 / PC Server 8595 - 486/50MHZ processor causes false ARTIC Portmaster diag error
Applicable to: AP-S, Canada, LA, United States
Source: H026988
Abstract: 486/50MHZ processor causes false ARTIC Portmaster diag error.
SYMPTOM:
When running diagnostics on the ARTIC Portmaster Adapter/A in an 8590 or 8595 with the 486/50MHZ processor card installed, a false 14220, E0DE error may occur.
PROBLEM ISOLATION AIDS:
Check the date of the Portmaster Adapter/A diagnostic file (DEV141.DGS) on the system reference diskette. Files dated 1-31-90 or earlier will exhibit the symptom.
FIX:
Download updated Portmaster Adapter/A option diskette from the web at the following URL:
http://204.146.167.209/artic/file_rep.html
SAS KEYWORDS:
8590SYSCOMM, D/T8590, D/T8595
|
Search Keywords |
8590SYSCOMM, D/T8590, D/T8595 | |
|
Hint Category |
Retain | |
|
Date Created |
16-11-98 | |
|
Last Updated |
16-11-98 | |
|
Revision Date |
16-11-99 | |
|
Brand |
IBM PC, IBM PC Server | |
|
Product Family |
PS/2, Server 95 | |
|
Machine Type |
8590, 8595 | |
|
Model |
Various | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
H026988 | |
|
Reverse Doclinks |
Date created: O91/08/06 |