IBM
pSeries Microcode Update for Cheetah 146LP Model ST3xxxx7LW/LC
18.2/36.4/73.4/146 GB
SCSI Hard Disk Drive. Microcode Level C50K(ROS Level 4335304B)
DATE:
Table of Contents
2.2 Determine Drive Model,
FRU&PN and Current Microcode Level
2.2.2 SCSI Drives attached to PCI SCSI RAID
Controllers
2.3 Transferring and Unpacking
the Microcode Update Package
2.3.1 Internet AIX self
extracting file (.bin)
2.4 Microcode Download
Procedure
2.4.1 SCSI Drives Attached to
SCSI Adapter
2.4.2 SCSI Drives Attached to
PCI RAID Adapter
3.1 Linux 2.6 kernel(such as SuSE SLES 9 or RHEL
4)
===============================================================
The Microcode files provided in this package
are only for use when installing disk drive microcode to a disk drive
installed in an IBM pSeries/RS6000 system using the AIX or Linux Operating
System.
Below is the list of microcode files in this package, these files are for use with the following pSeries SCSI disk drives ONLY:
NOTE: To insure the integrity of microcode files, please make sure the checksum value is correct after extraction
Size
Model FRU
# P/N Microcode File Name Checksum
------------ ---------- -------
------- -------------------------
----------
pSeries Internal Drives
18G (68 pin) ST318307LW 00P3061
00P2683 ST31830.53313030.4335304B
14003
18G (80 pin) ST318307LC 00P3063
00P2681 ST31830.53313032.4335304B
14003
18G (80 pin) ST318307LC 00P3064
00P2680 ST31830.53313033.4335304B
14003
18G (80 pin) ST318307LC 09P4437
00P2682 ST31830.53313034.4335304B
14003
36G (68 pin) ST336607LW 00P3065
00P2679 ST33660.53313130.4335304B
14003
36G (80 pin) ST336607LC 00P3067
00P2677 ST33660.53313132.4335304B
14003
36G (80 pin) ST336607LC 00P3068
00P2676 ST33660.53313133.4335304B
14003
36G (80 pin) ST336607LC 09P4447
00P2678 ST33660.53313134.4335304B
14003
73G (68 pin) ST373307LW 00P3069
00P2675 ST37330.53313230.4335304B
31859
73G (80 pin) ST373307LC 00P3071
00P2673 ST37330.53313232.4335304B
31859
73G (80 pin) ST373307LC 00P3072
00P2672 ST37330.53313233.4335304B
31859
73G (80 pin) ST373307LC 09P4890
00P2674 ST37330.53313234.4335304B
31859
146G(80 pin) ST314687LC 00P2665
00P2664 ST31468.53313333.4335304B
49411
146G(80 pin) ST314687LC 00P2669
00P2668 ST31468.53313334.4335304B
49411
2104
Drives:
18G (80 pin) ST318307LC 55P4068
55P4066 ST31830.44543032.4335304B
14003
18G (80 pin) ST318307LC 55P4070
55P4066 ST31830.44543132.4335304B
14003
36G (80 pin) ST336607LC 55P4073
55P4071 ST33660.44543033.4335304B
14003
36G (80 pin) ST336607LC 55P4075
55P4071 ST33660.44543133.4335304B
14003
73G (80 pin) ST373307LC 55P4078
55P4076 ST37330.44543034.4335304B
31859
73G (80 pin) ST373307LC 55P4080
55P4076 ST37330.44543134.4335304B
31859
146G(80 pin) ST314687LC 55P4083
55P4081 ST31468.44543035.4335304B
49411
146G(80 pin) ST314687LC 55P4085
55P4081 ST31468.44543135.4335304B
49411
Release
date |
MC Level |
Change Description
|
|
C50K |
-Changed drive
behavior when it fails DWD (Dropped Write Detect) self test, drive will not
go into read/write protect when self
test fails because of time-out, other fixes and enhancement |
|
C50J |
-Added DWD
(Dropped Write Detect) function for reliability enhancement (this change is
transparent to users), drive becomes “Write
Protect” when DWD offline test fails. -Disabled
Format Certification (Raid manager Format time is the same as AIX Diag format now) |
|
C50H |
This level of
code enables a feature that clears busy condition in rare situations that
drive reports busy status. |
|
C50F |
Fixes and enhancement for drive
to work with the new "PCI-X Ultra 320 Dual Channel SCSI Adapter"
and "PCI-X Dual Channel SCSI RAID Adapter". This level of code
supports 522 Bytes/sector format, and it is the minimum requirement for this
drive to function properly with new adapters. |
|
C50C |
Initial Released
version |
===============================================================
Approximately 20 minutes if
drive is part of rootvg(using Diagnostics CD); Approximately 5 minutes/drive if
drive is not part of rootvg(using concurrent
diagnostics).
2.2.1 SCSI
Drives attached to SCSI Controllers and
PCI-X RAID Adapters
To see the drive type and current
microcode level, Execute the following command:
lscfg -vl
hdisk* |pg
; For drives NOT configured for RAID
lscfg –vl pdisk* |pg ; For drives configured for RAID
Example of the info on a
18.2GB SCSI hard disk:
lscfg -vl hdisk1
DEVICE
LOCATION DESCRIPTION
hdisk1
10-68-00-13,0 16 Bit LVD SCSI Disk Drive (18200MB)
Manufacturer................IBM
Machine Type and
Model......ST318307LW
FRU Number..................00P3061
ROS Level and ID............4335304B
Serial Number...............3JK0031Q
EC Level....................0H11333
Part Number.................00P2683
Device Specific.(Z0)........000003129F00013E
Device Specific.(Z1)........1109C513
Device Specific.(Z2)........1000
Device Specific.(Z3)........01309
Device Specific.(Z4)........0001
Device Specific.(Z5)........22
Device Specific.(Z6)........162870 C
If the data returned in the “Part
Number”, “FRU Number”, and “Machine Type and Model” fields
match the one listed in section 1.1 AND the "ROS Level and ID...."
field of that data is below "4335304B",
this microcode applies. If this level is already installed then the "ROS
Level and ID...." shows: "4335304B "
Note: Drive microcode level in “ROS Level and ID …” field is displayed
in Hex value of ASCII characters in VPD data. Each alpha-numeric ASCII
character converts to a 2-digit hex number. For example in VPD displayed above,
43 Hex= ASCII character "C"; 35 Hex= ASCII character "5"; 30 Hex=ASCII character "0"; 4B Hex=ASCII character "K", microcode level is "C50K".
For SP systems with multiple nodes, you can use the following command to query all of the nodes at one time. Use of this command will also limit the amount of data returned, making it easier to audit. It returns only the pertinent information: node name, hdisk number, ROS Level and ID and part number.
dsh -a lscfg -v |egrep 'hdisk|ROS|Part'
pesp_n1:
hdisk0
10-60-00-0,0 16 Bit LVD SCSI Disk Drive (18200MB)
pesp_n1:
ROS Level and ID............4335304B
pesp_n1:
Part Number.................00P2683
pesp_n5:
hdisk0
10-60-00-0,0 16 Bit LVD SCSI Disk Drive (18200MB)
pesp_n5:
ROS Level and ID............4335304B
pesp_n5:
Part Number.................00P2683
pesp_n5:
hdisk1
10-60-00-8,0 16 Bit LVD SCSI Disk Drive (18200MB)
pesp_n5:
ROS Level and ID............4335304B
pesp_n5:
Part Number.................00P2683
At AIX command line, type:
Diag
Select "Task Selection" from diagnostics menu.
Select "PCI RAID Physical Disk Identify"
Select SCSI RAID Adapter (press enter, then F7 to Commit)
This will display the Vital Product Data for Physical
Disk drives attached to the RAID adapter.
===============================================================
a) Make a directory on an AIX system to receive the AIX
format file.
Enter: mkdir
/tmp/fwupdate
b) Transfer the AIX format file to /tmp/fwupdate
directory (using "Save as ...").
You'll see the filename is 146lp.bin
c) Unpack the file by executing the instructions below.
Enter the commands:
cd /tmp/fwupdate
chmod +x 146lp.bin
./146lp.bin
[Don't overlook the periods (.) in the above command.]
The directory 146lp with microcode files listed in section 1.1 will be added
to /tmp/fwupdate.
d-Enter the following command to copy the microcode files to " /etc/microcode " directory :
cp /tmp/fwupdate/146lp/ST3* /etc/microcode
e- If transferring files to a different system using floppy diskettes, use
the following procedure to copy files to diskette
Note: Don't overlook the complete path of microcode files, AIX Diag microcode download will not work if files are not
copied with complete path onto the diskette. Enter the following
command to copy microcode file(s) onto a floppy diskette
ls /etc/microcode/ microcodefilename | backup -ivf /dev/rfd0
where microcodefilename is microcode file that
is needed, for example:
ls /etc/microcode/ ST31830.53313030.4335304B | backup -ivf /dev/rfd0
Note: The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.
a) Make a directory on an AIX
system to receive the RPM format file.
Enter: mkdir
/tmp/microcode
b) Transfer the RPM format file to
the /tmp/microcode directory (using "Save as
...").
You'll see the filename is 146lp-C50K-AIX.rpm
c) Unpack the file by executing the
instructions below:
Enter the commands:
rpm -ihv
–ignoreos 146lp-C50K -AIX.rpm
The file size and checksum will be verified.
The microcode files will be added
to /etc/microcode/
Copy microcode updates from the CD-ROM to standard locations on your local disk:
1. RPM packaged microcode files
will be copied to "/tmp/microcode/RPM"
2. Microcode files will be copied to /usr/lib/microcode
Notes:
- "/etc/microcode" is a
symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated directory
or file then the user will be prompted for a new location.
========================================================
Warning: Do not power off the system or the drive during microcode download as this may permanently damage the disk drive
NOTE: Please save current and older versions of the microcode update files in case you need to restore your system.
Caution: The microcode download process is nondestructive to the hard disks; however, as a precaution, ensure that a backup operation has been performed on the affected systems PRIOR to the microcode installation.
Can microcode be installed Concurrently?
AIX level 5.1 and above supports concurrent microcode download on all drives,
including drives that are part of rootvg.
AIX level 4.33 and below does not support concurrent microcode download if
drive is part of rootvg, microcode download can ONLY
be performed in service mode(stand alone) using diagnostics CD. If disk is not
part of rootvg, microcode download can be performed cuncurrently as long as drive is not in use.
Is system reboot needed to activate the microcode: Yes if stand alone diagnostics is used, NO if concurrent diagnostics is used.
Installation Time: Approximately 20 minutes/drive if stand alone diagnostics is used(using Diagnostics CD); Approximately 5 minutes/drive if consurrent diagnostics is used.
2.4.1.1 AIX level 5.1 and above
2.4.1.2.1 Concurrent Download
1. Type diag
at the prompt.
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select resource that microcode will be applied to(hdisk? For physical disk, pdisk for RAID configured disks) and press ENTER, then
press "F7" to commit..
5- A small screen displays the message " *** NOTICE*** The microcode
installation occurs while the attached drives are available for use..... "
Press enter to continue
6. Select the source for microcode, use arrow key to go up/down, Enter to
continue.
/etc/microcode
diskette
- Use /etc/microcode if
"restore" command is used to copy files from diskette onto the disk
- Use diskette if using diskette as the source for download
NOTE: A prompt will ask you to insert the microcode diskette in diskette drive(if Diskette is selected above). Insert the diskette and press ENTER
7- Display shows a list of microcodes available for the selected drive, highlight option "M ST3xx...", the latest microcode for the drive and press ENTER. A message may warn you that current level of microcode is not available on the media, press ENTER to continue.
8. You will receive a msg. "Current Microcode
is...." and "Download has completed successfully"
(this may take a
few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic(and reboot if needed).
2.4.1.2
AIX level 4.33:
This procedure is for drives that are not part of rootvg or paging space:
1. This step is optional. Microcode download can
be performed either from Diskette or from Disk. To copy files from the diskette
to disk, place the diskette containing microcode files into diskette drive A,
at AIX Prompt type restore
2- At AIX prompt, type diag
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and press ENTER.
6. Press "F7" to commit.
(The current microcode level
of the resource you selected earlier will be displayed at the top of the
screen)
7. Make the following selections on the next screen:
Select Input Device
--------------------------------------- [ diskette]
<---------- Disk can be used if "restore" command is used in
step 1
Microcode level to download
----------------------------- [ latest]
Download latest level even if
------------------------------ [ yes]
current is missing
NOTE: A prompt will ask you to insert the microcode diskette into the floppy
drive(if Diskette is selected above). Insert the diskette which
accompanies these instructions. If this level is already installed in the drive
you've selected a message will let you know. A message also may come up to let
you know that the Diskette(or Disk) does not have the
previous level microcode file. This is true and is not required to complete the
download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode
is....and...Download has completed successfully"
(this may take a
few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic.
2.4.1.2.2 Standalone (Service Mode) Download
This procedure is used for all
drives including rootvg or paging space drives
1. Properly shutdown the system.
2. Boot up the system in standalone diagnostics mode with the CDROM diagnostics(Use diagnostics level 4.21 or above; It is
recommended to use the same level
of Diagnostic CD as the AIX ).
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER.
6. Press "F7" to commit.
(The current microcode
level of the resource you selected earlier will be displayed at the top of the
screen)
7. Make the following selections on the next screen:
Select Input Device
--------------------------------------- [ diskette]
Microcode level to download
-----------------------------[ latest]
Download latest level even if
-----------------------------[ yes]
current is missing
NOTE: A prompt will ask you to insert the microcode diskette into the floppy
drive. Insert the diskette which accompanies these instructions. If this
level is already installed in the drive you've selected a message will let you
know. A message also may come up to let you know that the Diskette(or
Disk) does not have the previous level microcode file. This is true and is not
required to complete the download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode
is...." and "Download has completed successfully"
(this may take a
few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic and reboot system in normal mode.
NOTE: Please save current and older versions of the microcode update files in case you need to restore your system.
1. At AIX Command line type:
diag
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select RAID controller from the list of resources,
PRESS ENTER, then F7 to commit
5. Select "Physical Disks" and PRESS ENTER
6. A list of all Physical Disks will be displayed,
select the disk that needs to be upgraded, PRESS ENTER and F7 to commit.
7. Select "Latest level"
8. Select "Disk" if files are copied to
/etc/microcode directory. Select "Diskette" if microcode files are
saved onto a diskette, PRESS ENTER
(The current microcode level of
the resource you selected earlier will be displayed at the top of the screen)
9. You
will receive a message "Download has completed successfully" and
"Current Microcode is" (this may take a few minutes).
10. Return to the Previous menu and repeat this procedure for each hard disk
that requires this microcode.
11. Exit diagnostic and reboot system.
2.4.3 SP systems
This procedure requires copying microcode files to the
appropriate SPOT(s). Therefore, it is HIGHLY recommended that someone with an
appropriate level of AIX experience and expertise should perform this task,
preferably the System Administrator of person(s) designated as responsible for
making software updates to the system.
Warning: Do not power off the system or the drive during microcode
download as this may permanently damage the disk drive
NOTE: Please save current and older versions of the microcode update files in case you need to restore your system.
Caution: The microcode download process is nondestructive to the hard disks; however, as a precaution, ensure that a backup operation has been performed on the affected systems PRIOR to the microcode installation.
Can microcode be installed Concurrently?
NO. If the disk is part of rootvg
or used as a paging device, microcode download can ONLY be performed while node
is "Network Booted" into "Diagnostic Standalone Mode".
Is system reboot needed to activate the microcode: Yes
Installation Time: Installation time will vary depending upon the system configuration
Procedure for SP System (Nodes):
Note: Make sure that node on which work is to be
performed has been "fenced" from the switch.
1. Obtain proper microcode diskette from your IBM
Service Representative.
2. Copy microcode file from diskette onto CWS:
restore -xvq
(file will be copied into
the "etc/microcode" directory)
3. Move microcode file from
"etc/microcode" directory to the appropriate Spot(s) that are used by
the customer for the node(s) to be updated.
ie:
/spdata/sys1/install/aix4??/spot/spot_aix4??/usr/lib/microcode
(??= level of AIX on your system)
4. To set the Node(s) to boot from network, from
CWS, run command:
spbootins
-r diag [frame#] [node#] [node count]
(example - - spbootins
-r diag 1 13 1)
5. From Perspectives, perform a
"Shutdown" for the node(s) to be updated.
6. From perspectives screen for node to be updated,
select "Network Boot" and wait for TTY to open to DIAG MENU.
7. Choose "Task Selection".
8. Choose your terminal type.
9. Select "Download Microcode"
10. Select resource that microcode will be applied
to(hdisk?) and PRESS ENTER.
11. Press "F7" to commit.
(The current microcode
level of the resource you selected earlier will be displayed at the top of the
screen)
12. In the "Select the input device"
screen, make sure settings are as follows:
Select Input Device
--------------------------------------- [ disk]
Microcode level to
download ----------------------------- [ latest]
Download latest level
even if ------------------------------ [ yes]
current is missing
PRESS "F7" to commit
13. You will receive a msg. "Current
Microcode is" and "Download has completed successfully"
(this may take a
few minutes)
14. On CWS run the following command:
spbootins
-r disk [frame# [node#] [node count]
15. On CWS, After spbootins
finishes, run the following command:
splstdata
-b (check output to see that node in question was set back to disk)
16. On "TTY" screen for node, Press F10
to get to "Shutdown Screen" and close TTY screen.
17. On perspectives screen of affected node, do a
power off of the node and a power on of the node.
18. After node boots, telnet to the node, run the
following command and check that correct microcode level has been updated.
lscfg -vl hdisk#
(ie hdisk0,hdisk1 etc).
======================================================
Microcode can be updated using
the iprconfig utility. The iprconfig
utility
allows for multiple levels of adapter and device microcode to
exist on the
system at the same time. After the device to update microcode is
selected, all available microcode levels are presented to choose to
download.
1.
a) If using
SLES 9 base, install the package by typing:
rpm -ivh --ignoreos 146lp-C50K -AIX.rpm
b) If using SLES 9 SP1 or better or RHEL 4
or better, install the package by typing:
rpm -ivh 146lp-C50K
-LINUX.rpm
2. Update the microcode by
typing:
iprconfig
Press Enter.
3. Select Download microcode and
press Enter.
4. Select the device you wish to
update by typing a 1 then pressing Enter. Multiple devices may be selected.
5. Select the microcode image to
be downloaded to the device by typing a 1 then pressing Enter.
6. Press Enter again to
confirm the download (display shows “Microcode Download in
Progress” with elapsed time)
7. If multiple devices were selected,
repeat from Step 5 for the next device.
To check the microcode level:
1. Start iprconfig
utility,
2. Select "Display hardware
status" option.
3. Select disk to query by
typing a 1 next to it and pressing "Enter"
4. Look at the "Firmware
Version" field
--------------------------------------------------------------------------
Microcode can be updated using
the iprupdate utility. If iprupdate
finds newer
microcode on the system it will be downloaded to the disk.
1. Install the package by
typing:
rpm -ivh --ignoreos 146lp-C50K-AIX.rpm
Press Enter.
2. Update the microcode by
typing:
iprupdate
Press Enter.
To check the microcode level:
1. Start iprconfig
utility,
2. Select "Display disk
hardware status" option.
3. Find the disk you wish to
query and note its serial number.
4. Type "d" to get to
the "Display disk unit details" screen.
5. Select disk to query by
typing a 5 next to it and pressing "Enter"
6. Look at the "Firmware
Version" field
-------------------------------------------------------------------------
Microcode can be updated using
the sisupdate utility. If sisupdate
finds newer
microcode on the system it will be downloaded to the disk.
1. Install the package by typing:
rpm -ivh --ignoreos 146lp-C50K-AIX.rpm
Press Enter.
2. Update the microcode by
typing:
sisupdate
Press Enter.
To check the microcode level:
1. Start sisconfig
utility,
2. Select "Display disk
hardware status" option.
3. Find the disk you wish to
query and note its serial number.
4. Type "d" to get to
the "Display disk unit details" screen.
5. Select disk to query by
typing a 5 next to it and pressing "Enter"
6. Look at the "Firmware Version" field