This level of firmware is for FC 5716, PN: 80P4543, 03N6441,03N7069 FC
1977, PN: 80P6101, 80P6455, 03N6439, 03N7067, FC 1957, PN: 03N4698, 03N6440,
03N7068
The typical time to install the microcode is .4 hr.
|
|
1.91a5 |
|
1.90X13 |
|
1.90A4 | GA level |
It is recommended firmware upgrades be performed during a scheduled maintenance window and that the system be re-booted following firmware download.
Machine type 7039-651 must be at system firmware level 3J030521 or higher. If the system firmware level is less than 3J930521 you can damage the fibre channel adapter if you attempt to upload the fibre channel adapter firmware.
To determine machine type, enter the following command:
lscfg -pl sysplanar0 | grep Model | awk ' {print $2}'
If machine type is "IBM,7039-651", check the system firmware level by entering the following command:
lsmcode -rt system
NOTE: firmware level RJ030206 is a lower level than 3J030521. To compare firmware levels, compare the trailing 6 characters. For firmware levels RJ030206 and 3J030521, you compare the trailing 6 characters: 030206 is less than 030521
1) List the Fiber Channel PCI adapters installed in the system by typing:
lsdev -C | grep "fcs"
Note the device names of all the Gigabit Fiber Channel PCI Adapters installed. The adapter device names will be fcsX, where X is 0,1, or some other number.
2) There are two methods to check the current microcode level on the adapter.
lscfg -vl fcsX
Where X is the number of the adapter returned by the previous lsdev command.
The Command will produce output similar to
DEVICE LOCATION DESCRIPTION
fcs1 P1-C1-T1 FC Adapter
Part Number.................80P4543
EC Level....................A
Serial Number...............1A31600450
Manufacturer................001A
Feature Code................280B
FRU Number.................. 80P4544
Device Specific.(ZM)........3
Network Address.............10000000C9332A79
ROS Level and ID............02881914
Device Specific.(Z0)........1001206D
Device Specific.(Z1)........00000000
Device Specific.(Z2)........00000000
Device Specific.(Z3)........03000909
Device Specific.(Z4)........FF801315
Device Specific.(Z5)........02881914
Device Specific.(Z6)........06831914
Device Specific.(Z7)........07831914
Device Specific.(Z8)........20000000C940F419
Device Specific.(Z9)........TS1.90x13
Device Specific.(ZA)........T1D1.90x13
Device Specific.(ZB)........T2D1.90x13
Device Specific.(YL)........U7879.001.DQD0JHD-P1-C1-T1
If the firmware level in the "Z9" field is less the 1.91a5, then the microcode should upgraded.
lsmcode -d fcsX
Where X is the number of the adapter returned from the "lsdev" command above.
DISPLAY MICROCODE LEVEL 802111
fcs3 FC Adapter
The current microcode level for fcs3 is 1903013.
Use Enter to continue.
F3=Cancel F10=Exit Enter
191105 is the extension of the firmware image (df1000fa.191105) that was last loaded on the adapter.
If the extensions is less than 191105, then the firmware should be upgraded.
You will want a copy of the description and one of the above formats.
You may transfer the files to
the target system in one of the following ways:
Detailed download /unpacking instruction follow for each format.
6.1 AIX RPM Package
Downloading RPM Format File to Target Server
Use this method to download to an AIX system:
Note: The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.
1. Make a directory on an AIX system to receive the RPM format file.
Enter: mkdir /etc/microcode
2. From the download website, follow the website instructions to download the package. If your initial download is not to the target system, you can use ftp to move the file(s) to the target system..
You'll see the filename is pci.df1000fa-1-91A5.aix.noarch.rpm
3. Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv --ignoreos pci.df1000fa-1-91A5.aix.noarch.rpm
4. If the firmware unpacks successfully, the microcode files will be added to /etc/microcode/
5. The file size and checksum will be verified on the unpacked firmware image, NOT the RPM file.
File size: 664748
Checksum: 48915
If step 3 returns with: " package package_name is already installed"
You will need to uninstall the rpm package as follows:
rpm -e package_name
Where "packag_name" is the package name returned in the failure of step three.
Now go to step 3 above to unpack the firmware.
6.2 Linux RPM Package
Downloading Linux RPM Format File to a Linux Server
Use this method to download to an Linux system:
Note: The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.
1. Make a directory on an AIX system to receive the RPM format file.
Enter:
2. From the download website, follow the website instructions to download the package. If your initial download is not to the target system, you can use ftp to move the file(s) to the target system..
You'll see the filename is pci.df1000fa-1-91a5.linux.noarch.rpm
3. Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv --ignoreos pci.df1000fa-1-91A5.Linux.noarch.rpm
4. If the firmware unpacks successfully, the microcode files will be added to /etc/microcode/
5.The file size and checksum will be verified on the firmware image, NOT the RPM file.
File size: 664748
Checksum: 48915
If step 3 returns with: " package package_name is already installed"
You will need to unistall the rpm package as follows:
rpm -e package_name
Where "packag_name" is the package name returned in the failure of step three.
Now go to step 3 above to unpack the firmware.
The Diagnostic Microcode Download software supports the following naming
convention for the microcode binary file :
df1000fa.191105 where 191105 is the version of the file.
7.1 Using the AIX Command-Line Method
You are now ready to FLASH the EEPROM in the adapter using the single command:
diag -d fcsX -T download
Where X is the number found from the "lsdev -C | grep fcs " command.
Self-explanatory menus will step you through the microcode installation.
Repeat each step in 7.1 above for all the cards that need the update.
To Back level the firmware
diag -d fcsX -T "download -f -l previous"
7.2 Using the Download Microcode Diagnostic Service Aid Method
From the command line login, log in as root.
Enter
diag
Select
Task Selection (Diagnostics, Advanced Diagnostics, Service Aids, etc.)
Select
Download Microcode
Select the device returned for above
fcs*
Press enter when prompted to download the microcode
Upon completion, a message will state that the firmware has be successfully downloaded and that
the new level is 191105.
Exit.
7.3 Using the Linux lputil Method
To update the Fiber Channel PCI adapter microcode on installed adapters in a Linux system the Emulex lputil flash program must be used. This program is included in an Application Kit availble only from the IBM OEM web pages on the Emulex web site. Some versions of Linux will also require an Application Helper Module also available from the IBM OEM web pages on the Emulex web site.
In some cases, the IBM OEM web page may list an updated driver for the Linux version installed on the target server. The updated Driver Kit includes both an updated driver and the corresponding Application Helper Module. You should consider installing the updated Driver Kit along with the Application Helper Module.
To begin, open the IBM OEM web page by entering http://www.emulex.com/ibm/support/index.jsp in an Internet browser. Follow links on the page to the LP9802 IBM Branded Fiber Channel PCI adapter page. This page will contain a list of supported drivers for this adapter.
Scroll down to the "Drivers for Linux" or the "Previous Releases" section. Find the entry in the table which corresponds to the Linux driver version currently installed on the target server as determined in section 5.2 above. Download the Application Kit or Driver Kit and, if needed, the Application Helper Module to a temporary directory on the target server. Follow the installation instructions provided on the IBM OEM web page to install the downloaded packages.
Once both the Application Helper Module Kit or Driver Kit and the Application Kit have been installed on the target, updating the microcode can proceed as follows.
- Begin by confirming proper installation of Application Kit and Application Helper Module.
Verify lputil command is present, type ls /usr/sbin/lpfc/lputil Output should list file path for lputil command.
Verify Driver Module (lpfc of lpfcdd) is loaded, type lsmod Examine output for presence of lpfc or lpfcdd in loaded module list. If not present, type modprobe lpfc or modprobe lpfcdd, examine console messages for error reported.
Verify Helper Module (lpfcdfc) is loaded, type lsmod Examine output for presence of lpfcdfc in list. If not present, type modprobe lpfcdfc, examine console messages for error reported.If any of the verification checks fail, review the installation documentation and insure all steps were completed, look for any errors reported during installation. If problems cannot be resolved, contact IBM service support.
- Since firmware update will reset the Fiber Channel adapters, you should unmount any storage devices controlled by the adapter being updated before proceeding.
Caution: Do not interrupt this process, shutdown the system or remove power until the firmware update process is complete.
- Start the utility by typing: /usr/sbin/lpfc/lputil
- From the Main menu, enter 3, Firmware Maintenance
- If more than one HBA is installed, select the HBA to be updated.
- Enter 1, Load Firmware Image
- Enter the full path to the firmware file, /lib/firmware/pci.00dffa00.191105, press enter.
- Wait for message indicating update process is complete.
- Enter 0 twice to exit the utility, the new firmware has been flashed to the adapter.
If you are updating the firmware on a dual-channel HBA, repeat steps 3 through 8 to update the firmware on the second port.
Back to Contents
7.4 Verifying the Update on AIX
1 List the Fiber Channel PCI adapters installed in the system by typing:
lsdev -C | grep "fcs"
Note the device names of all the Gigabit Fiber Channel PCI Adapters installed. The adapter device names will be fcsX, where X is 0,1, or some other number.
2 There two methods to check the current microcode level for the adapter.
- The first method uses the "lsmcode" command
lsmcocde -d fcsX
Where X is the number of the adapter returned from the "lsdev" command above.
DISPLAY MICROCODE LEVEL 802111
fcs3 FC Adapter
The current microcode level for fcs3 is 191105.
Use Enter to continue.
F3=Cancel F10=Exit Enter
If current microcode level is 191105, then the firmware has been upgraded.
- The second method uses the "lscfg" command
lscfg -vl fcsX
Where X is the number of the adapter returned by the previous lsdev command.
The Command will produce output similar to
DEVICE LOCATION DESCRIPTION
fcs1 P1-I1/Q1 FC Adapter
Part Number.................80P4543
EC Level....................A
Serial Number...............1E313BB001
Manufacturer................001E
FRU Number.................. 80P4544
Device Specific.(ZM)........3
Network Address.............10000000C93AF096
ROS Level and ID............02881914
Device Specific.(Z0)........1001206D
Device Specific.(Z1)........00000000
Device Specific.(Z2)........00000000
Device Specific.(Z3)........03000909
Device Specific.(Z4)........FF801314
Device Specific.(Z5)........02881913
Device Specific.(Z6)........06831913
Device Specific.(Z7)........07831913
Device Specific.(Z8)........20000000C93AF096
Device Specific.(Z9)........TS1.91A5
Device Specific.(ZA)........T1D1.91A5
Device Specific.(ZB)........T2D1.91A5
Device Specific.(YL)........P1-I1/Q1
If the firmware level in the "Z9" filed is 1.91a5, then the firmware has been upgraded
7.5 Verifying the Update on Linux
On Linux systems one of two possible methods must be used to determine the current level of Microcode on installed adapters. If the first method does not display the Microcode level, the second method should display the Microcode level for installed adapters. Both methods assume you are logged in as root and one or more Fiber Channel PCI adapters are installed.
- The first method generally works on systems running Linux 2.4 kernels and some systems running 2.6 kernels which do not have full support for the /sys filesystem.
- List Fiber Channel PCI adapter information for all installed adapters by typing:
cat /proc/scsi/lpfc/*
Output will display various information for each installed Fiber Channel PCI adapter. Make note of Firmware Version:
Firmware Version: 1.91 (H2D1.91a5)- The second method works on systems running Linux 2.6 and higher kernels which support the /sys file system.
- Determine which host numbers are assigned to installed Fiber Channel PCI adapters by typing:
cd /sys/class/scsi_host
find . -name "lpfc_drvr_version" -printOutput will list relative path names for each installed Fiber Channel PCI adapter. Note the host{n} portion of each path.
./host2/lpfc_drvr_version
./host1/lpfc_drvr_version- Display Firmware version for each installed Fiber Channel PCI adapter by typing:
cat host{n}/fwrev
Where host{n} is one from step 1. Firmware version will display as follows:
1.91 (H2D1.91a5)
If the firmware level in displayed using either method is 1.91a5, then the firmware has been upgraded
Privacy | Legal | Contact IBM