PSF/AIX PCL translate with duplex or bin selection
ITEM: RTA000090712
Q:
ABSTRACT: PSF AIX PCL translate with duplex or bin selection
SEARCH ARG: PCL AFP AIX DUPLEX
TOPIC THREAD: PRINT
AFP
PSF6000
..
The sales manual indicates that PSF for AIX V 2.1 has transform
limitations:
"PCL transform discards device control statements, such as are used for
duplex or bin selection."
My customer is a service bureau who may get all types of PCL data
streams. They are looking at both the 3900 Wide Duplex and 3829
printers. If they get a PCL job that needs to be run duplex for the
entire job, I understand that a formdef could be created to do this
for the 3829 and with N-up on the 3900 WD. But if a PCL job switches
from duplex to simplex back and forth,(or bin selection switches back
and forth) how do I code my formdef? Does the pcl to afpds translate
insert IMMs to allow for a formdef copygroup support? If not, how
can I (if at all) print this type of job?
A:
The implementation of the PCL transform in PSF/AIX will ignore those
| commands altogether. Infoprint Manager V3.1 with current PTFs,
| however, will provide the support you're seeking. Please review the
| web pages on the external PSC site for additional information.
| Thanks for using ViewBlue.
| Revised 03 May 1999
S e a r c h - k e y w o r d s:
AIX PSF/6000 PSF FOR AIX PCL DUPLEX BIN DEVICE IGNORED pcl2afp controls
command psf/aix infoprint manager ipmgr
WWQA: ITEM: RTA000090712 ITEM: RTA000090712
Dated: 05/1999 Category: XPSF6000
This HTML file was generated 2000/11/30~13:34:04
Comments or suggestions?
Contact us