ITEM: AD3665L
trcfmt error message 0454-036
Question:
   Env: SNA Server/6000, AnyNet APPC over TCP/IP, DDCS/6000
   Desc: I am trying to format an AnyNet trace. It gives me the
        error message: 0454-036  The register rwf_six exceeds the
        maximum count of three. 
   Action: You told me that connection is to the host. I told you 
        that you need Partner LU 6.2 Location profile, since the
        host is a LEN node. 
        You have added the profile but still were getting the 
        error same message.
           Next Action: The reason you are getting the above error message
        is bug in /etc/trcfmt program which is called by trcrpt.
        In order to fix it perform the following:
           cd /etc
           vi trcfmt
           search for the string 'bbl_diag_dma_complete' in the
           statement:
                038 { "bbl_diag_dma_complete " $subfunc, \\
                        01 { "ERR xmalloc() failed" }, \\
                        02 { "ERR copyin() failed" }, \\
                        03 { "ERR xmdetach() failed" }, \\
                        04 { "ERR unpinu() failed" } \\
                    } \\
        remove space and the "\\" on the last line and rerun.
   Test Case: SE reran the command. It worked fine.
Response: