can not connect to RISC using AADU
Question:
I have AADU and DOS 6.1.  When I start AADU, it gives me an error 
message on the PC : C:\\drive no longer valid.
Response:
It has been a known problem.  AADU on DOS 6.1 is not a zuipported
configuration.  In order to make it work together, you have to do
the following on the PC:
        Reboot PC and immediately press F5 to prevent CONFIG.SYS and
        AUTOEXEC.BAT from being interpreted and executed.  
        Add the following line to the CONFIG.SYS file:
           DEVICE=C:\\DOS\\SETVER.EXE
        At the DOS prompt enter the following line:
           setver pciinit.exe 5.00
        If the DEVICE line was added in step 1, DOS will display 
        a warning message about loading SETVER, which can be ignored.
        Reboot the PC.  PCIINIT will now run successfully.