1210 OR 1225 ERRORS ON 8550 MODELS 031,061

1210 OR 1225 ERRORS ON 8550 MODELS 031,061

PURPOSE:
PROVIDE INSTRUCTIONS TO DETERMINE IF THE DUAL ASYNC CARD INSTALLED IN AN 8550 MODELS 031,061 SHOULD BE REPLACED FOR 1210 OR 1225 ERRORS WHILE RUNNING DIAGNOSTICS.

PHYSICAL CHECK:
AFFECTED DUAL ASYNC CARDS (FRU P/N34F0008) ARE IDENTIFIED BY LOCATING RAW CARD PART NUMBER 90X8074 (UPPER LEFT CORNER) ON THE COMPONENT SIDE OF THE CARD.

DETAIL:
ERROR CODE 1210 INDICATES A DUAL ASYNC PORT 1 REGISTER TEST FAILURE. ERROR CODE 1225 INDICATES A DUAL ASYNC PORT 2 REGISTER TEST FAILURE.

ERROR CODE 1210 OR 1225 MAY OCCUR WHILE RUNNING DIAGNOSTICS ON AN 8550 MODELS 031,061 WITH A DUAL ASYNC CARD INSTALLED. IF THIS CONDITION EXISTS AND THE DUAL ASYNC CARD MATCHES THE ABOVE MENTIONED PHYSICAL CHECK, REPLACE THE CARD (FRU P/N34F0008).