8570 A61 OR A21 FAILS TO OPERATE W/NEW BUSMASTER ADAPTER

8570 A61 OR A21 FAILS TO OPERATE W/NEW BUSMASTER ADAPTER

REPLACE THE SYSTEM BOARD, P/N15F7657, TO CORRECT A COMPATIBILITY PROBLEM WITH CERTAIN BUSMASTER ADAPTERS.

PHYSICAL CHECK:
AN 8570 25MHZ 386 SYSTEM HAVING A SYSTEM BOARD WITH A BAR CODE LABEL OF B1HCHXXX OR LOWER PRINTED ON IT THAT CONTAINS A SCSI HARDFILE ADAPTER OR OTHER BUSMASTER ADAPTER THAT HAS EXPERIENCED OUT OF BOX FAILURES. TO CHECK THE BAR CODE LABEL LOOK AT THE 5TH LETTER FROM THE LEFT.

 EXAMPLE        B1HC( H )XXXX
                              |
                              |
  THE KEY LETTER IS  LOCATED HERE.  "A" THROUGH "H" QUALIFIES
  THE SYSTEM BOARD.

NOTE
BUSMASTER ADAPTERS USUALLY CONTAIN A MICROPROCESSOR AND HAVE THE CAPABILITY OF CONTROLLING DATA TRANSFER ON THE MICROCHANNEL BUSS, INDEPENDENTLY OF THE SYSTEM MICROPROCESSOR. DUE TO VARIATIONS IN DESIGN, VISUAL IDENTIFICATION OF A BUSMASTER MAY BE DIFFICULT. IN THESE CASES REFERRING TO THE ADAPTER DOCUMENTATION SHOULD HELP DETERMINE IF THE FAILING ADAPTER IS A BUSMASTER ADAPTER.

DETAIL:
SOME 8570 MODEL A61 OR A21 SYSTEMS REQUIRE A LATER LEVEL SYSTEM BOARD WHEN OPERATING WITH SOME BUSMASTER ADAPTERS. BUSMASTER ADAPTERS THAT FAIL TO OPERATE PROPERLY AFTER BEING INSTALLED CORRECTLY REQUIRE THIS ECA IF THEY PASS DIAGNOSTICS AND MEET THE REQUIREMENTS OF THE ECA'S PHYSICAL CHECK.