PHYSICAL CHECK:
ON SOME CARDS, ONE END OF COMPONENT "L2" IS INSTALLED IN THE
WRONG HOLE. COMPONENT "L2" IS LOCATED NEAR THE LOWER 15 PIN
CONNECTOR (PORT 2). ONE END OF "L2" IS CORRECTLY CONNECTED TO
PIN 5 OF THE PORT 2 CONNECTOR. THE OTHER END SHOULD BE CONNECTED
TO GROUND (THE HOLE NEAREST TO THE PORT 2 CONNECTOR). SOME CARDS
WERE MANUFACTURED WITH THIS END OF "L2" CONNECTED TO -12 VOLTS.
SEE DIAGRAM BELOW: DUAL ASYNC CARD
_______________________________________________________ | DUAL ASYNC CARD _|_ PORT 1 | (CORRECT HOLE IS GROUND) | | | | | | | | |___| | V _L2_ _|_ PORT 2 | (INCORRECT -12 VOLTS) ------->O O----|____|-5-| | | | | |________________________ ___ _______ |___| |____| |________| |___|
THE SYSTEM WILL NOT POWER UP WHEN AN EXTERNAL DEVICE (PRINTER, PLOTTER, MODEM, ETC.) IS CONNECTED TO PORT 2 OF THE DUAL ASYNC CARD.THIS INCLUDES ANY DEVICE THAT HAS SIGNAL AND FRAME GROUND CONNECTED TOGETHER. IF THE DEVICE DOES NOT HAVE THE TWO GROUNDS CONNECTED TOGETHER, THE SYSTEM WILL POWER UP. HOWEVER, THE DEVICE WILL NOT BE FUNCTIONAL WHEN CONNECTED TO PORT 2. TO DETERMINE IF THE DEVICE IS FUNCTIONAL, IT SHOULD BE TESTED IN PORT 1.TO IDENTIFY AN INCORRECTLY WIRED CARD SEE "PHYSICAL CHECK" SECTION OF THIS DOCUMENT.