PHYSICAL CHECK:
Systems experiencing data transfer read or write errors such as:
CRC checks, post 601, 602, 10480, 10481, 10490 and 10491 errors,
or other system hangs and lockups during data transfers are
eligible for this ECA.
PREREQUISITES:
P70 systems below serial number xx-xx50000 should
also be serviced if a multi-tasking operating system
is installed.
DETAIL:
Some 8573 power supplies may transmit RFI that interferes with
diskette and fixed disk operation. This RFI signal could affect
any 8573 system.
The types of problems that may occur include, but are not limited to the following:
COPPER TAPE KIT FRU P/N07G1680
The kit contains a diagram and twelve inches of copper tape
needed for one power supply.
To install the copper tape lift the clear plastic shield
covering the side and top of the supply. Install the 1 inch wide
copper tape length wise across the top and side of the supply
so it covers the seam opening. This tape will prevent RFI from
escaping from any space between the top and side covers by
ensuring conductivity between these two surfaces. RFI
transmissions can escape between two electrically insulated
pieces of conductive material.
Note:
The rear vent holes are
electrically connected to each other so the RFI can not pass
through them.