PHYSICAL CHECK:
AFFECTED DRIVES ARE KNOWN TO HAVE BEEN SHIPPED IN THE ABOVE
SYSTEM MODELS, HOWEVER NOT ALL OF THESE SYSTEMS WILL HAVE THE
AFFECTED FIXED DISKS.
TO DETERMINE IF A DRIVE IS ELIGIBLE FOR THIS ECA INSPECT THE
DRIVE TO ENSURE THAT IT IS AN ST-177I 60MB FIXED DISK
MANUFACTURED FOR IBM BY SEAGATE. ONLY THIS MODEL SEAGATE DRIVE
THAT FAILS POST WITH THE FOLLOWING SYMPTOMS IS ELIGIBLE FOR THIS
ECA:
NOTE:
IF THE FIXED DISK HAS AN LED LIGHT ON THE DRIVE, THE LIGHT
WILL BLINK 9 TIMES AT POST. THE LIGHT WILL STAY ON
APPROXIMATELY ONE MINUTE, THEN BEGIN BLINKING AGAIN AND
THE 10483 ERROR WILL REMAIN DISPLAYED. SOME 8570 FIXED
DISKS DO NOT HAVE AN LED. THE 8570 HARDFILE EXTERNAL LED
(NEAR THE POWER SWITCH) WILL NOT BLINK, AND SHOULD NOT BE
USED TO IDENTIFY THIS FAILURE.
DETAIL:
SOME 60MB FIXED DISKS IN 8550, 8555, AND 8570 SYSTEMS MAY
FAIL TO SPIN AT POWER-ON. THIS ECA PROVIDES A REPLACEMENT
DRIVE FOR THOSE MEETING THE PHYSICAL CHECK REQUIREMENTS.
IF AN AFFECTED FIXED DISK FAILS TO SPIN AFTER MULTIPLE POWER-ON ATTEMPTS, AND THE CUSTOMER'S DATA IS NOT BACKED-UP, THE FOLLOWING PROCEDURE MAY RESTORE TEMPORARY OPERATION OF THE DISK:
REPLACE THE 60MB FIXED DISK WITH FRU P/N6128282 FOR THE 8555 AND WITH FRU P/N6128294 FOR THE 8550 AND 8570 SYSTEMS. (FRU P/N6128282 IS THE EUROPE EQUIVALENT OF FRU P/N85F0049)