           S P L O T  -  The Pen Plotter Simulator V3.0 for Win32
           ------------------------------------------------------
                   Copyright (C) 1991-96 by Alexandr NOVY
                             All rights reserved.

                               November 1996


                                 HPGL2.TXT

        This file contains  some reference information  about HP-GL/2
        support provided by the SPLOT program.

        The 32-bit version of the SPLOT  program supports HP-GL/2 pen
        plotters and HP-GL/2 raster devices.

        The implemented support of the HP-GL/2 language is based on
        "The HP-GL/2 and HP RTL Reference Guide - A Handbook for 
        Program Developers", Hewlett Packard 2nd edition,
        September 1996.


        1) Important parameters:
        ========================
        Number of pens: user defined up to 256.
        For pen plotters the number of pens is physical number of
        pens in carousel.
        For pen plotters the following modulo function is used for
        pen numbers greater than number of pens (np):
                        pn = ( (pn-1) mod np ) + 1
        For raster devices the number of pens is maximum number of
        logical pens, the actual number of logical pens is defined
        by NP instruction and its default value is 8 for color
        raster devices and 2 for monochrome raster devices. However
        only color raster devices are supported now.
        For raster devices the following modulo function is used for
        pen numbers greater or equal to current number of pens (np):
                        pn = ( (pn-1) mod (np-1) ) + 1
        Note that for raster devices the pens are numbered from zero
        and pen number 0 is valid pen. However it is usually white
        colored and all white pens are not used when the transparency
        mode is on (default state) (see TR instruction).
        For pen plotters the pen number 0 causes storing of a current
        pen to carousel and no pen is used.

        Paper size: user definable (see the PAPERS.TXT file)
                    or defined by the PS instruction

        Plotter unit: 0.025 mm

        Maximal number of digits in decimal fraction to be read: 8

        Supported character fonts (typefaces):
         The present version of the HP-GL/2 interpreter supports only
        the  stick  fonts  (characters  are  drawn  as  a  series  of
        vectors). The scalable outline fonts or bitmap fonts are  not
        supported. Note that not all HP-GL/2 devices support  outline
        or bitmap fonts, but all HP-GL/2 devices support stick fonts.
         From stick fonts only fixed-vector font (typeface number 48)
        and drafting  font (typeface  number 49)  are supported.  The
        variable spacing fonts are not supported yet. Also the  fixed
        arc font is not supported yet. Note that the drafting font is
        for use  with the  HP Drafting  character set  (character set
        number 563).

        Supported character sets:
         The present version of the HP-GL/2 interpreter supports only
        these character sets:
        --------------------------------------------------------------
         Character |                                     |
         Set Value |            Description              | ISO Number
        --------------------------------------------------------------
            0      | Roman8 (default)                    |    --
          277      | Roman8 (default)                    |    --
           21      | ANSI US ASCII                       |     6
          531      | HP-GL Download                      |    --
          563      | HP-GL Drafting                      |    --
          595      | HP-GL Special Symbols               |    --
           11      | JIS ASCII                           |    14
           85      | ISO International Reference Version |     2
          115      | ISO Swedish                         |    10
           19      | ISO Swedish for Names               |    11
            4      | ISO Norway v1                       |    60
           36      | ISO Norway v2                       |    61
           39      | ISO German                          |    21
            6      | ISO French v1                       |    25
           37      | ISO United Kingdom                  |     4
            9      | ISO Italian                         |    15
           83      | ISO Spanish                         |    17
          147      | ISO Portuguese                      |    16
            7      | HP German                           |    --
          275      | HP Latin Spanish                    |    --
            5      | Roman Extensions                    |    --
           43      | Katakana                            |    --


        2) Alphabetical list of HP-GL/2 instructions that are fully
           supported by the SPLOT program:
        ===========================================================
         AA  - The Arc Absolute Instruction
         AR  - The Arc Relative Instruction
         AT  - The Absolute Arc Three Point Instruction
         CI  - The Circle Instruction
         CO  - The Comment Instruction
         CP  - The Character Plot Instruction
         CR  - The Set Color Range for Relative Color Data
               (for raster devices only)
         CT  - The Chord Tolerance Mode Instruction
         DF  - The Default Values Instruction
         DI  - The Absolute Direction Instruction
         DL  - The Download Character Instruction
         DR  - The Relative Direction Instruction
         DT  - The Define Label Terminator Instruction
         DV  - The Define Variable Text Path Instruction
         EA  - The Edge Rectangle Absolute Instruction
         EP  - The Edge Polygon Instruction
         ER  - The Edge Rectangle Relative Instruction
         ES  - The Extra Space Instruction
         EW  - The Edge Wedge Instruction
         FP  - The Fill Polygon Instruction
               However the optional non-zero winding fill method
               is supported only for solid fills.
         IN  - The Initialize Instruction
         IP  - The Input P1 and P2 Instruction
         IR  - The Input Relative P1 and P2 Instruction
         IW  - The Input Window Instruction
         LB  - The Label Instruction
         LO  - The Label Origin Instruction
         LT  - The Line Type Instruction
         MG  - The Message Instruction
               Writes a message to the SPLOT Event Log window.
         NP  - The Number of Pens Instruction 
               (for raster devices only)
         PA  - The Plot Absolute Instruction
         PC  - The Pen Color Assignment Instruction
               (for raster devices only)
         PD  - The Pen Down Instruction
         PE  - The Polyline Encoded Instruction
         PM  - The Polygon Mode Instruction
         PR  - The Plot Relative Instruction
         PS  - The Plot Size Instruction
         PU  - The Pen Up Instruction
         PW  - The Pen Width Instruction
         RA  - The Fill Rectangle Absolute Instruction
         RO  - The Rotate Coordinate System Instruction
         RR  - The Fill Rectangle Relative Instruction
         RT  - The Relative Arc Three Point Instruction
         SA  - The Select Alternate Font Instruction
         SC  - The Scale Instruction
         SI  - The Absolute Character Size Instruction
         SL  - The Character Slant Instruction
         SM  - The Symbol Mode Instruction
         SP  - The Select Pen Instruction
         SR  - The Relative Character Size Instruction
         SS  - The Select Standard Font Instruction
         TR  - The Transparency Mode Instruction
               (for raster devices only)
         UL  - The User-Defined Line Type Instruction
         VS  - The Velocity Select Instruction (for information only)
         WG  - The Fill Wedge Instruction
         WU  - The Pen Width Unit Selection Instruction


        3) Alphabetical list of HP-GL/2 instructions that are
           partially supported by the SPLOT program (they may
           be fully supported in next SPLOT versions):
        ======================================================
         AD  - The Alternate Font Definition Instruction
               Only the character set attribute is supported.
               All other attributes are ignored.
               The character size (pitch and height attributes)
               should be specified by the SI or SR instruction.
               The stroke weight attribute is always considered
               to be 9999 (the characters are drawn in the current
               pen width).
               The typeface is always considered to be 48 (stick
               font) except for character set number 563 (HP-GL
               Drafting).
         BP  - The Begin Plot Instruction
               Only the initialization (IN) part is supported.
         FT  - The Fill Type Instruction
               Only the fill types 1,2,3,4 are supported.
         SD  - The Standard Font Definition Instruction
               See the AD instruction.
         TD  - The Transparent Data Instruction
               When transparent data mode is enabled, SPLOT 
               prints all control characters as spaces.


        4) Alphabetical list of HP-GL/2 instructions that are not
           supported by the SPLOT program:
        =========================================================
         - All Dual-Context Extension instruction.
         - All output instructions:
            OD, OE, OH, OI, OP and OS.
         - And these:
           AC  - The Anchor Corner Instruction *
           BR  - The Bezier Relative Instruction *
           BZ  - The Bezier Absolute Instruction *
           CF  - The Character Fill Mode Instruction
           DC  - The Digitize Clear Instruction
           DP  - The Digitize Point Instruction
           EC  - The Enable Cutter Instruction
           FR  - The Frame Advance Instruction *
           LA  - The Line Attributes Instruction *
                 Only round line ends and line joins
                 are supported yet.
           LM  - The Label Mode Instructrion *
           MC  - The Merge Control Instruction
           MT  - The Media Type Instruction
           NR  - The Not Ready Instruction
           PG  - The Advance Full Page Instruction *
           PP  - The Pixel Placement Instruction
           QL  - The Quality Level Instruction
           RF  - The Raster Fill Definition *
           RP  - The Replot Instruction
           ST  - The Sort Instruction
           SV  - The Screened Vectors Instruction

                 * - may be supported in next SPLOT versions