                               S95 Register

     By  default  S95=0 gives the computer-modem (DTE)  connect  speed.  So
whatever  speed  (19,200   38,400   57,600) you have set,  the  modem  will
respond  in kind, even if the modem-modem connect is 2400. S95=1 will  give
true  modem-modem connect speed (DCE), ie; a 2400 CARRIER will say  CONNECT
2400.  S95=2 will add /Arq to default for error correction conections,  ie;
CONNECT  19,200/Arq.  S95=3 will give modem connect speed  with  /Arq   ie;
CONNECT 2400/Arq. If your software recognizes /Arq it may be a good idea to
add it, via the S95 register.

>>>NOTE:  When the modem gives DTE (computer-modem) connect speed, if  your
software shows 'efficiency' of transfer, it will be LOW. If the modem sends
CARRIER  (DCE)  as connect speed, then 'shown' efficiency  should  approach
100%.

     If  you  want the Carrier, Protocol & Compression, with DTE  then  use
S95=44. To get the same with DCE speed, use S95=45. You can add 2 to either
(46  or  47)  which will add the /ARQ, but as you already  have  the  other
messages it is redundant.

     The  default S36=7 enables buffering so that the modem-computer  speed
may differ from the modem-modem speed.

>>NOTE<<  Except for QMODEM, all the sofware I have seen does NOT show  any
results  beyond  CONNECT  xxx/ARQ.  You  can see  the  results  if  you  do
ATDTphoneumber in Terminal mode.

                                   Don Hinds - Zoom Tech
##include=c:\text\signa.tif