EMM386.EXE Err Msg: WARNING: User Specified Ranges Overlap


The information in this article applies to:
  • Microsoft MS-DOS operating system versions 5.0, 5.0a, 6.0, 6.2, 6.21, 6.22
  • Microsoft Windows versions 3.1, 3.11
  • Microsoft Windows for Workgroups versions 3.1, 3.11


SYMPTOMS

When you use the EMM386.EXE exclude switch X=MMMM-NNNN, you may receive the following error message:

WARNING: User Specified Ranges Overlap.
Press any key when ready...
For example, this error message can be generated with the following CONFIG.SYS file command:
device=c:\dos\emm386.exe x=F000-FFFF


CAUSE

This error occurs when the ranges you are including and excluding overlap, or when you attempt to exclude memory in the ff00-ffff range.


RESOLUTION

To eliminate the error message, exclude a range below ff00 and ensure the ranges you are including and excluding do not overlap. The largest range you can exclude is A000-FEFF.


MORE INFORMATION

The F000-FFFF range is not included in the EMM386.EXE search algorithm. If you are using EMM386.EXE version 4.45 or later, you can have EMM386.EXE search this range by adding the HIGHSCAN parameter. The F000- FFFF address range is typically occupied by the System ROM BIOS.

Additional query words: 6.22 4.20 4.33 4.44 4.45 4.48 5.00 5.00a 6.00 6.20 wfw wfwg win31 x= i= errmsg err msg 3.10

Keywords :
Issue type :
Technology :


Last Reviewed: December 14, 2000
© 2001 Microsoft Corporation. All rights reserved. Terms of Use.


Article ID: Q78925

Last Reviewed:
December 14, 2000

Send to a friend

Provided by
Microsoft Product Support Services


Did the information in this article help answer your question?

Yes
No
Did not apply

Please provide additional comments about this information.
(255 character max)