2.992 bytes

Service Hints & Tips

Document ID: MCGN-3QNQWC

Server Options - 3518 Synchronization may fail with 2.25GB

Applicable to: World-Wide

SYMPTOM:
"Check Consistency" errors during synchronization of RAID 5 Logical drives, or Defunct (DDD) drives with any RAID level may be experienced.

PROBLEM ISOLATION AIDS:

All of the following must be true for this Tip to apply:

- There are more than 6 x 2.25GB Hard Drives FRU p/n76H0958 (Option p/n's 07H0387 / 94G2650 / 70G9862) in a IBM 3518 External Storage Enclosure with daisey-chained backplanes

- The backplane (s) that these drives are connected to are daisey-chained.

- The 3518 is attached to any RAID / ServeRAID / ServeRAID II Adapter / Controller in a IBM PC Server / Netfinity server.

FIX:
Connect each populated Backplane in the 3518 to a separate SCSI Channel.

Refer to RETAIN TIP Record# H133777 for additional info on backplane jumper settings.


SAS KEYWORDS:
PSY2 PSY2DASD UNCLASSIFIED D/T3518
DEFUNCT DDD P/N76H0958 P/N07H0387
P/N94G2650 P/N70G9862


Search Keywords

PSY2, PSY2DASD, UNCLASSIFIED, D/T3518, DEFUNCT, DDD, P/N76H0958, P/N07H0387, P/N94G2650, P/N70G9862

Hint Category

Hard Drives, Retain

Date Created

12-01-98

Last Updated

12-01-99

Revision Date

12-01-2000

Brand

IBM PC Server

Product Family

Rack/Storage Enclosures

Machine Type

3518

Model

Various

TypeModel

Retain Tip (if applicable)

H125499

Reverse Doclinks
and Admin Purposes

USA=A, EMA=A, AFE=A, Owning B.U.: USA