2.584 bytes |
Service Hints & Tips |
Document ID: DETR-44KK3Q |
Aptiva - 2144/2168 (SL-C) Diagnostics - Mouse
Applicable to: World-Wide
Note: A sticking keybutton can cause the mouse to operate incorrectly.
If you suspect this, go to "Keyboard" .
___
|001|
|___|
- Power off the system unit.
- Make sure the ball turns freely.
- Insert the Advanced Diagnostics diskette into drive A.
- Power on the system unit.
- Make a note of any error messages, then press Esc.
- Press 0 (SYSTEM CHECKOUT), then press Enter.
- Press Y, then press Enter.
- Press 0 (RUN TESTS ONE TIME), then press Enter.
- Run the Mouse tests.
- Follow the instructions on the screen.
DO THE MOUSE DIAGNOSTIC TESTS RUN WITHOUT ERRORS?
Yes No
| |
| |__
| |002|
| |___|
| - If you receive any error except an 8613 error replace the mouse.
| - If you receive an 8613 error, replace the system board.
|
|__
|003|
|___|
- The system unit is operating normally.
- If the symptom remains, replace the mouse.
--------------------------------------------------------------------------------
Search Keywords |
| |
Document Category |
Diagnostics, Input Devices | |
Date Created |
28-01-99 | |
Last Updated |
28-01-99 | |
Revision Date |
| |
Brand |
IBM Aptiva | |
Product Family |
Aptiva | |
Machine Type |
2144, 2168 | |
Model |
22P; 24P; 25P; 29P; 14P; 26P; 62P; 66P; 16P; 82P; 86P; 27P; 83P; 22F; 24F; 25F; 26F; 62F; 27F; 18P; 19P; 20P; WM1; WM2; SW2; 743; 843; 744; 754; 853; 854; 755; 766; 866; 784; 785; 787; 887; 789; 889; 797; 745; 767; 855; 756; 786; 782; 788; 888; 792; 798; 768; 856; 857; 8K2; S86; S82; T82; H55; H66; H77; H78; H89; H92; H67; H80; H81; H90; H93; L55; L66; L77; L78; L89; L92; L67; L80; L81; L90; L93; K66; K77; KB1; KB2; K78; K89; K92; KB3; K67; K80; K81; KB4; MB4; KB5; MB5; K90; K93; KB6; X65; X70; X88; X79; X89; X90; Y65; Y70; Y78; Y84; Y88; Y79; Y89; Y90; 26J; 68J; 62J; 27J; 28J; 63J; 64J; 65J | |
TypeModel |
| |
Retain Tip (if applicable) |
| |
Reverse Doclinks |